Brand Name : Schneider Electric
Model Number : OsiSense XCKN, XCKM, XCE etc.
Certification : CE,CCC etc.
Place of Origin : China
MOQ : 12pcs
Price : USD8~USD25/unit
Payment Terms : T/T, Western Union
Supply Ability : 10,000pcs/month
Delivery Time : 5-8 working days or bulk order negotiate
Packaging Details : Standard export carton
Product Name : Limit Switch, Travel Switch
Type : Sensor
Control Volt : 380VAC, 220VDC
Mechanical life : 10 Million cycles
Electrical life : 300 Thousand cycles
Environment temperature : -15~60 degree Celsius
Contact : 1 NO + 1 NC
Schneider Electric XCKN, XCE Compact Limit Switch Industrial Controls OsiSense Actuating Head Plunger Rotating Arm Roller
Mechanical limit switches are contact sensing devices widely used for detecting the presence or position of objects in industrial applications. The term limit switch is derived from the operation of the device it-self. As an object (or target) makes contact with the operator of the switch, it eventually moves the actuator to the "limit" where the elec-trical contacts change state.
 Through this mechanical action, electrical contacts are either opened (in a normally closed circuit) or closed (in a normally open circuit). Inductive proximity, capacitive proximity, and photoelectric sensors perform this same process through non-contact sensing.
Features and Benefits of Limit Switches
  Can be used in almost any industrial environment
  Very precise in terms of accuracy and repeatability
  Consume little electrical energy
  Can switch loads with high inductance
  Can control multiple loads
 Limitations of Limit Switches
  Generally restricted to equipment operating at relatively low speeds.
  Must make direct contact with target.
  Moving mechanical parts will wear out.
Limit Switch Terminology
Pretravel — the distance or angle that the actuator must go through to trip the contacts
 Operating Point — position of the actuator at which the contacts snap to the operated position
 Release Point — the position of the actuator at which the contacts return to their original state
 Differential — distance (degrees) between contacts trip and contacts reset
 Overtravel — movement of the actuator beyond the contacts trip point
 Initial Position — position of actuator when no external force is ap-plied to the actuator
 Some other important terms associated with limit switches:
 Operating force (torque) — force required to move the actuating element
 Minimum return force (torque) — minimum force required to return actuator to its initial position
 Total Travel — the maximum allowable distance the actuating ele-ment can travel
 Repeat Accuracy — ability of a switch to repeat its characteristics precisely from one operation to the next operation
Travel switch is applicable to electric circuit with voltage not more than AC Ue 380V/50- 60Hz or DC Ue 220V and current not more than AC Ie 0.8A or DC Ie 0.16A as travel control, direction of motion or speed change of movement mechanism, automatic control of machine tool, limit action & travel or procedure control of movement mechanism. Standard: GB 14048.5,IEC60947-5-1,CCC China Compulsory Product Certification
  
| Product Series | OsiSense | 
|---|---|
| Serial Number | Standard type | 
| product type | Limit switch | 
| Sensor design | Compact | 
| Ontology type | Fixed | 
| Manipulator type | Rotating head | 
| material | plastic | 
| Body material | plastic | 
| Head material | plastic | 
| Fixed mode | Ontology | 
| Operating head movement | Rotate | 
| Head type | Spring return roller rocker thermoplastic variable length | 
| Method type | Side movement, 2 directions | 
| Cable entry hole | 1 for M20x1.6 cable gland, cable outer diameter: 7...13 mm | 
| Number of poles | 2 | 
| Contact type | 1 NC + 1 NO | 
| Contact action | Momentary | 
| Switch trigger | 30° convex edge | 
|---|---|
| Electrical connections | Screw clamp terminal, clamping force: 1 x 0.34...2 x 1.5 mm2 | 
| Line insulation | Zb | 
| Forced to open | Have | 
| Forced to open minimum torque | 0.15 Nm | 
| Minimum trigger torque | 0.1 Nm | 
| Maximum operating speed | 1.5 m/s | 
| Contact line specification | A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A in accordance with EN/IEC 60947-5-1 Appendix A R300, DC-13 (Ue = 250 V), Ie = 0.1 A in accordance with EN/IEC 60947-5-1 Appendix A | 
| Rated insulation voltage [Ui] | 300 V compliant with UL 508 500 V (pollution level 3) in accordance with IEC 60947-1 300 V compliant with CSA C22.2 No 14 | 
| Rated impulse withstand voltage [Uimp] | 6 kV in accordance with IEC 60664 6 kV in accordance with IEC 60947-1 | 
| Short circuit protection | 10 A fuse fuse, type gG | 
| Electrical life | 5000000 times, DC-13, 120 V, 4 W, working rating <60 times/min, load factor: 0.5 in accordance with IEC 60947-5-1 Appendix C 5000000 times, DC-13, 24 V, 10 W, working rating <60 times/min, load factor: 0.5 in accordance with IEC 60947-5-1 Appendix C 5000000 times, DC-13, 48 V, 7 W, working rating <60 times/min, load factor: 0.5 in accordance with IEC 60947-5-1 Appendix C | 
| Mechanical life | 10000000 times | 
| width | 30 mm | 
| height | 108...157 mm | 
| depth | 42 mm | 
| product weight | 0.18 kg | 
| ISO n°1 terminal | (21-22) NC (13-14)NO | 
| Impact resistance | 45 gn for 11 ms in accordance with IEC 60068-2-27 | 
|---|---|
| Vibration resistant | 25 gn (f= 10...500 Hz) in accordance with IEC 60068-2-6 | 
| IP protection level | IP65 in accordance with IEC 60529 | 
| IK protection level | IK04 according to EN 50102 | 
| Overvoltage type | Class II complies with IEC 61140 Class II complies with NF C 20-030 | 
| Operating temperature | -25...70 °C | 
| Storage ambient temperature | -40...70 °C | 
| Protection process | TC | 
| certified product | CCC | 
| Standards compliant | EN 60947-5-1 EN 60204-1 UL 508 IEC 60204-1 IEC 60947-5-1 CSA C22.2 No 14 | 






|   | 
| XCKN XCE Compact Limit Switch Industrial Controls OsiSense Actuating Head Plunger Rotating Arm Roller Images | 
 3TF IEC AC Motor Contactor Current Range 09~400A AC-3 AC-1 Compact Installation
                                                                                    
                        
                        
                        
                                                            3TF IEC AC Motor Contactor Current Range 09~400A AC-3 AC-1 Compact Installation
                                                    
                        
                     Digital 1/3 Phase Low Voltage Components 600V 50A Ammeter Voltmeter PN-666s
                                                                                    
                        
                        
                        
                                                            Digital 1/3 Phase Low Voltage Components 600V 50A Ammeter Voltmeter PN-666s
                                                    
                        
                     AC 1A 5A Digital Multifunction Meter , 380/400V 3 Phase Power Meter RS485
                                                                                    
                        
                        
                        
                                                            AC 1A 5A Digital Multifunction Meter , 380/400V 3 Phase Power Meter RS485
                                                    
                        
                     Water Pump Control Box AC Motor Contactor 3 Phase AC380/400V One Use One Back
                                                                                    
                        
                        
                        
                                                            Water Pump Control Box AC Motor Contactor 3 Phase AC380/400V One Use One Back
                                                    
                        
                     DOL Magnetic AC Motor Contactor Starter 4-63kW AC-3380V For Squirrel Cage Motor
                                                                                    
                        
                        
                        
                                                            DOL Magnetic AC Motor Contactor Starter 4-63kW AC-3380V For Squirrel Cage Motor
                                                    
                        
                     20-80A Integrated Motor Protector 0.25~80kW 220V AC-3 380V Squirrel Cage Motor
                                                                                    
                        
                        
                        
                                                            20-80A Integrated Motor Protector 0.25~80kW 220V AC-3 380V Squirrel Cage Motor
                                                    
                        
                     9A~95A AC Motor Contactor 1810 2510 3210 6511 AC-3 AC-1 Coil Voltage 24V 110V
                                                                                    
                        
                        
                        
                                                            9A~95A AC Motor Contactor 1810 2510 3210 6511 AC-3 AC-1 Coil Voltage 24V 110V
                                                    
                        
                     Motor Control Cabinet AC Motor Contactor Fan Start Reduced Voltage 380V~415V 3
                                                                                    
                        
                        
                        
                                                            Motor Control Cabinet AC Motor Contactor Fan Start Reduced Voltage 380V~415V 3
                                                    
                        
                     LS GMC Contactor 3P 4P 9A 12A 18A 32 40A 50A 65A 75A 85A AC-3 AC-1 Highly
                                                                                    
                        
                        
                        
                                                            LS GMC Contactor 3P 4P 9A 12A 18A 32 40A 50A 65A 75A 85A AC-3 AC-1 Highly
                                                    
                        
                     3RT6016 IEC Contactor 7 9 12 25 32 40 50 63 80 185A AC-3 AC-1 Coil Voltage 24V
                                                                                    
                        
                        
                        
                                                            3RT6016 IEC Contactor 7 9 12 25 32 40 50 63 80 185A AC-3 AC-1 Coil Voltage 24V